Stainless steel tank with high and low design

Hot dip galvanized steel water tank
The overall structure of the stainless steel tank is divided into two kinds of high water tank and low water tank. Let's take a look at the differences between the two designs:
High water tank inlet and outlet to be considered with the entire system, the design has more specificity, the water pipe placed in the higher water tank, the diameter generally by flow, the low water tank has a direct pipe to the steady flow tank water supply, The tank inlet pipe can be smaller.
100m3 panels combined SMC/GRP/FRP water storage tank food grade
Low water tank cavity installed in the steady flow tank on the booster pump group, electric control cabinet, etc., steady flow tank from the municipal pipe network and water tank, the structure of the compact design, with particular attention to the beautiful.
If the high water tank is relatively large, can be calculated according to the daily average flow, or according to the average hourly flow calculation, tentative DN40, DN50, DN65 third gear, 0.6MPa flange connection, inlet pipe should be with float valve, In the right side of the tank. The outlet pipe is located at the lowest point of the tank, the diameter of the pipe is determined according to the flow rate of the matching equipment, 0.6MPa flange connection.
1.22mm*1.22mm galvanized water tank panel
Standard outlet pipe on the left side of the tank, the water tank overflow pipe diameter is generally larger than the inlet pipe 1-2, on the side of the highest water tank, the bottom of the pipe position is higher than the floating valve valve closed position 20-30mm or so. Overflow pipe can not be installed on the valve, should be dust, pest control and other measures, stainless steel water tank can be used with PVC pipe and discharge pipe merger.
Standard overflow pipe on the left side of the tank, the drain pipe diameter is generally not less than DN50, from the bottom of the tank outlet, plus the elbow from the side of the tank after the introduction of the gate valve access to the sewer.
Standard discharge pipe on the left side of the tank, the top of the tank should have ventilation pipe, pipe diameter is generally not less than DN50, should be dust, pest control and other measures, generally should be set down the nozzle, ventilation tube can not be installed valve.
Hot-dipped Galvanzied Sectional Water Storage Tanks for Water Treatment
Stainless steel tank can be considered in the air pipe installed on the air filter.
The top of the tank should be manhole, manhole arranged in the side of the inlet pipe, easy to repair floating ball valve; manhole side should have escalators, escalators and manhole blocks on the ear with M10 bolts. Standard manhole, escalator on the right side of the tank.
The lowest side of the tank at the appropriate location left R1 / 2 interface, then the ball valve installed after the level gauge.
Stainless steel water tank to take into account the bottom of the tank to lead out the drain pipe, the base is generally used 10 # channel, the middle of the same channel with a meter square grid.
Fire water storage tanks
BYF series in the installation of the corresponding position of the steady flow of welding the same channel, and pre-drilling steady flow tank installation hole.
Place the φ70 hole on the side of the channel to be drained to the drain pipe for the drain pipe (DN50) to pass through.
For more information, please visit our website: www.grp-watertank.com, or contact us with E-mail, our E-mail address is rask@coolingtowerfiller.com, you can also chat us straightly on whatsapp: 008618330029204, you can also call our boss straightly: 008615930159213